Generator - Northern Lights M944W3 12 kW

S/N NL944-77120
📍Engine room, port Hours6,875 h (16 Nov 2026) Avg use2.7 h/day

Notes

How it works

Check oil and coolant before start, raw-water seacock open. Start, confirm exhaust water, let it warm before applying load. Remove load and run 3-5 min before stopping.

Known issues

Shuts down on high temp: raw-water flow (impeller, strainer, seacock). Won't start: fuel, glow plugs, start battery, or a safety shutdown (low oil/high temp) - check the panel fault code. Running light for long periods causes wet stacking - give it load.

Planned maintenance

StatusTaskIntervalLast doneNext due
Overdue Change generator oil and filter
33 days overdue / 12 h overdue
yearly / 250 h 23 Oct 2025
6,613 h
23 Oct 2026
at 6,863 h
Due soon Replace generator anodes
in 2 days
6-monthly 31 May 2026 27 Nov 2026
OK Inspect generator belts
in 118 days / in 226 h
yearly / 500 h 23 Mar 2026
6,601 h
23 Mar 2027
at 7,101 h
OK Replace generator fuel filters
in 254 days / in 303 h
yearly / 500 h 06 Aug 2026
6,678 h
06 Aug 2027
at 7,178 h
OK Replace generator raw-water impeller
in 196 days / in 861 h
yearly / 1,000 h 09 Jun 2026
6,736 h
09 Jun 2027
at 7,736 h
OK Replace generator coolant
in 436 days / in 1,411 h
every 2 years / 2,000 h 04 Feb 2026
6,286 h
04 Feb 2028
at 8,286 h
OK Generator full service by technician
in 575 days
every 2 years 23 Jun 2026 22 Jun 2028

Unplanned maintenance

Nothing unplanned recorded.

Service history

14 Nov 2026 Replaced leaking exhaust elbow gasket
Weep at elbow flange found on daily round. Replaced gasket, torqued, ran 1 h under load - dry.
Jamie Cole
06 Aug 2026
6,678 h
Replace generator fuel filters
Completed as per procedure.
Priya Shah
23 Jun 2026 Generator full service by technician
Completed as per procedure.
Priya Shah
09 Jun 2026
6,736 h
Replace generator raw-water impeller
Completed as per procedure.
Jamie Cole
31 May 2026 Replace generator anodes
Completed as per procedure.
Sam Taylor
23 Mar 2026
6,601 h
Inspect generator belts
Completed as per procedure.
Sam Taylor
04 Feb 2026
6,286 h
Replace generator coolant
Completed as per procedure.
Priya Shah
23 Oct 2025
6,613 h
Change generator oil and filter
Completed as per procedure.
Priya Shah

Diagrams, plans & photos

Diagrams & plans · 1

Where it is Open

Hour meter readings

10 Nov 20266,855 hJamie Cole
03 Nov 20266,825 hJamie Cole
27 Oct 20266,815 hJamie Cole
20 Oct 20266,751 hJamie Cole
13 Oct 20266,720 hJamie Cole
06 Oct 20266,755 hJamie Cole
29 Sep 20266,742 hJamie Cole
22 Sep 20266,683 hJamie Cole
15 Sep 20266,569 hJamie Cole
08 Sep 20266,685 hJamie Cole

Fluids & capacities

Coolant
Engine oil

Inventory

Fuel filter, secondary
24-14102 · ER port locker 2, bin B
3 pcs (min 2)
Oil filter
24-15016 · ER port locker 2, bin A
4 pcs (min 3)
Raw-water impeller kit
24-21011 · ER port locker 2, bin A
1 pcs (min 2)
Zinc anode, heat exchanger
24-23100 · ER port locker 2, bin C
0 pcs (min 4)

Manuals & files

Generator AC output and changeover Wiring diagram · 1 p.

Components & parts 8 components · 4 parts

Raw-water pump impeller 24-21011 · 0 parts
Impeller kit
Fuel filter, secondary 24-14102 · 0 parts
Oil filter 24-15016 · 0 parts
Air filter element 24-11020 · 0 parts
Drive belt 24-21550 · 0 parts
Zinc anode, heat exchanger 24-23100 · 0 parts
Thermostat 24-23510 · 0 parts
Exhaust elbow gasket 24-33440 · 0 parts